Documentation — Sensors & calibration
MS41 Live / Docs / Sensors & calibration
Sensors & calibration
The System › Inputs & sensors page of the editor holds the load mode, the lambda sensor type, the input pins and the calibration of the MAP sensor and the wideband. Two linear formulas cover almost every sensor.
Settings marked FLASH in the editor take effect after a flash; settings marked LIVE can be changed with the engine running. On this page everything needs a flash except the clutch switch input.
Load mode and lambda sensor
| Setting | Choices |
|---|---|
| Fuel / load mode | VE table (MAP sensor) — the MS41 Live mode: the VE, AFR target and ignition tables of the editor; no MAF needed. MAF and speed density with the stock BMW maps — legacy modes, not supported, kept only to read older tunes. The editor flags them and offers to switch to the VE table. |
| Lambda sensor | Wideband (0–5 V controller), recommended — closed loop on the AFR target table, lean-AFR protection available. One stock narrowband (bank 1) or two stock narrowbands — possible but not recommended: the stock regulation around lambda 1 only. Keep the AFR target at 14.7 outside full load. |
Changing the lambda sensor type involves several calibration values that belong together. Use Lambda sensor: full preset on that page: it sets the sensor type, the lambda channels, the idle closed-loop steps and the delay before closed loop all together, and can be undone in one go.
VE mode with a wideband is the configuration that has been driven, and the one MS41 Live is built for. The narrowband modes have not been validated on a car.
MAP sensor
kPa = slope × V + offset
Enter the slope in kPa per volt and the offset in kPa (the pressure the sensor would report at 0 V), or pick a preset.
| Preset | Calibration |
|---|---|
| Bosch 3 bar (0 281 002 437) | 0.4 V = 20 kPa · 4.65 V = 300 kPa |
| AEM 3.5 bar (30-2130-50) | kPa = 86.18 × V − 43.09 |
| GM 3 bar (12223861) | kPa = 63.16 × V + 1.05, stored with an offset of 0 |
These presets come from the sensors’ documentation; they have not been measured on a car. Check them as described below.
The offset cannot be positive. The ECU can only subtract it. For a sensor with a positive offset, the editor stores 0: check the pressure read with the engine off and adjust the slope if needed.
Check
- Engine off, ignition on: the MAP gauge must show barometric pressure — about 101 kPa at sea level, roughly 1.2 kPa less per 100 m of altitude. Compare with a local weather station (station pressure, not sea-level pressure).
- At a warm idle, a healthy stock engine sits somewhere around 26–30 kPa (the development M52B25).
- For a second point, a hand vacuum pump with a gauge on the sensor port is enough.
Wideband controller
AFR = a × V + b (gasoline scale: 14.7 = lambda 1)
Enter AFR per volt (a) and AFR at 0 V (b), or pick a preset. MS41 Live works on the gasoline AFR scale whatever the fuel: 14.7 always means lambda 1, and the stoichiometric ratio of your fuel is a separate setting on the Engine & injectors page. Configure the controller’s analog output for gasoline AFR.
| Preset | Output | Status |
|---|---|---|
| AEM X-Series (30-0300 / 30-0310) | AFR = 2.375 × V + 7.3125 | used on the development car |
| Innovate LC-1 / LC-2 / MTX-L, default output | AFR = 3.0 × V + 7.35 | from documentation — check |
| 14Point7 Spartan 2 / 3, default output | AFR = 2.0 × V + 10.0 | from documentation — check |
| PLX, default output | AFR = 2.0 × V + 10.0 | from documentation — check |
Not-ready threshold
Below this voltage the controller is considered “not ready” (heating up, or in fault): no closed loop and no lean-AFR protection. For the AEM X-Series the value is 0.55 V. Set it for your controller: its manual says what the analog output does while the sensor heats.
Check
- Compare the editor’s AFR gauge with the controller’s own display at a steady idle and at a steady cruise. They should agree closely.
- If they differ by a constant amount, look at the analog ground first: it belongs on the sensor ground, see Wiring.
Input pins
MAP sensor, wideband and clutch switch each have an input setting: Lambda 1 pin (75), Lambda 2 pin (76) or MAF signal pin (8); the wideband and the clutch switch can also be set to “none”. Without a wideband there is no AFR-based closed loop and the lean-AFR protection is inactive. The editor warns when two functions share a pin.